Automation · Yaskawa

Yaskawa VFD supply in India

Need a Yaskawa VFD in India for a new panel or a breakdown replacement? Industrisol supplies Yaskawa variable frequency drives including A1000, GA800, V1000, J1000 and P1000, sized to your motor kW, supply voltage and load.

  • Models from small single-motor drives to 175 HP class
  • Fan and pump drives as well as general purpose and vector drives
  • Like-for-like replacement quotes from your drive label
  • Supplied from Mumbai to customers across India
Yaskawa A1000 VFD

Sizing a Yaskawa VFD correctly

Selecting a VFD by motor kW alone is a common mistake. A drive should be chosen on motor full-load current at your supply voltage, with the right duty rating:

  • Normal Duty (ND) suits variable torque loads such as centrifugal fans and pumps, where the drive rarely sees high overload.
  • Heavy Duty (HD) suits constant torque loads such as conveyors, mixers, hoists and compressors that need high starting torque and short-term overload.

Also check the supply (200 V or 400 V class, single or three-phase), whether a braking resistor is needed for fast stops or overhauling loads, and the enclosure the VFD will sit in. For a breakdown replacement, the model code on the drive label tells us the series, voltage class and rating.

Yaskawa VFD models available

Specification notes below are typical for the listed models. Confirm exact ratings for your order with us.

Yaskawa A1000 variable frequency drive

Yaskawa A1000 VFD

High-performance vector VFD for induction and permanent magnet motors, with a 5-line LCD keypad and flexible I/O.

Input Three-phase 200–240 V AC (400 V class also available)
HP range (240 V) 0.75–150 HP HD, 0.75–175 HP ND
Motor types Induction, permanent magnet
Max output frequency 400 Hz (1000 Hz optional)
I/O Switchable NPN/PNP inputs, 3 Form A + 1 Form C outputs, 1–32 kHz pulse input
Keypad 5 line x 16 character LCD
Yaskawa GA800 VFD

Yaskawa GA800 VFD

Current general-purpose Yaskawa VFD with built-in DC link choke and braking transistor on many ratings.

Input Three-phase
Output voltage 200 V class: 200–240 V; 400 V class: 380–480 V
DC link choke Built in on models 2110–2415 and 4060–4720
Braking transistor Built in on models 2004–2138 and 4002–4168
Protection Electronic thermal overload, heatsink thermistor, DC bus charge LED
Humidity 95% RH or less, non-condensing
Yaskawa V1000 compact VFD

Yaskawa V1000 VFD

Compact current vector VFD, commonly used on small conveyors, compressors and packaging machines.

Example rating 3.7 kW (5 HP)
Input 440 V three-phase
Control Open-loop current vector
Yaskawa J1000 micro VFD

Yaskawa J1000 VFD

Small V/f VFD for simple speed control of fans, pumps, conveyors and small machines, with minimal setup.

Input 415 V class
Control V/f
Mounting Compact, side-by-side
Yaskawa P1000 fan and pump VFD

Yaskawa P1000 VFD

VFD designed for variable torque fan and pump applications such as HVAC, water supply and process pumps.

HP range 0.75 to 175 HP
Input Three-phase, 200 V class (400 V class also available)
Enclosure IP20
Cooling Fan cooled
Display Digital

Match the VFD to the load

Load Duty Yaskawa VFD to consider
Centrifugal pumps, fans, blowers Normal Duty P1000, GA800, A1000
Small conveyors, mixers, shutters Heavy Duty J1000, V1000
Compressors, hoists, packaging Heavy Duty V1000, A1000, GA800
High-performance machines, PM motors Heavy Duty A1000, GA800

Replacing a failed Yaskawa VFD

01

Photograph the label

Send a clear photo of the drive nameplate showing the full model code and the motor nameplate.

02

Note the setup

If the keypad still works, note or copy key parameters. Many Yaskawa drives support parameter copy via the keypad or a USB copy unit.

03

Get options

We quote the same model where available, or a current Yaskawa equivalent with a note on any wiring or parameter differences.

04

Install and commission

Your electrician or system integrator installs the new drive and re-enters parameters or runs auto-tuning.

FAQ

Frequently asked questions

Still have a question? Call +91 90433 36700 or send an enquiry.

How do I choose the right size Yaskawa VFD?

Use the motor full-load current and your supply voltage, then pick Normal Duty for fans and pumps or Heavy Duty for conveyors, compressors and hoists. Choose a drive whose rated output current for that duty is equal to or above the motor current. We can size it for you from the motor nameplate.

Which Yaskawa VFD is best for pumps and fans?

P1000 is designed for variable torque fan and pump loads. GA800 and A1000 are also used for pumps where more features or networking are needed. For small single pumps, a compact J1000 or V1000 can be sufficient.

Do I need a braking resistor with my Yaskawa VFD?

Only if the load must stop faster than it would coast, or if it can drive the motor, such as hoists or high-inertia fans. Many Yaskawa models have a built-in braking transistor, so only an external resistor is needed. Share your stopping time and load details.

Can a Yaskawa VFD cause harmonics in my plant?

Like all six-pulse drives, VFDs draw non-sinusoidal current. Built-in DC chokes on larger GA800 and A1000 ratings reduce this. For many drives on one supply, consider harmonic filters or a low-harmonic drive such as U1000.

How do I get a Yaskawa VFD price?

Send the motor kW, voltage, load type and quantity, or a photo of your existing drive label, through Request a quote or call +91 90433 36700. We reply with current pricing for the matched model.

Get the right Yaskawa VFD

Send your motor nameplate or old drive label and we will quote a correctly sized Yaskawa VFD.