Spraying, misting & dust suppression
Mist nozzle and fog nozzle manufacturer in Mumbai
Industrisol is a mist nozzle manufacturer and supplier for Mumbai and customers across India. We make low pressure and high pressure mist and fog nozzles in brass and SS316 for evaporative cooling, humidification, dust suppression, odour control and greenhouses.
- Low pressure push-fit and high pressure misting nozzles
- Brass bodies with stainless steel tips, and SS316 options
- Anti-drip versions for clean shut-off
- Matched to your pump pressure and droplet target
Talk to our team
Need a price, alternative or spec check?
Share the model, quantity and application. We reply with suitable options and a quotation.
- Phone: +91 90433 36700
- Email: industrisol@industrisol.com
Mist, fog or spray: what is the difference?
Full cone and hollow cone patterns break down into a fine fog or mist a short distance from the orifice. Whether a discharge is called a fog, a mist or a spray depends on its mean droplet size. Small droplets hang in the air and evaporate quickly, which is what makes misting useful for cooling and humidifying.
A hydraulic nozzle produces finer droplets as pressure rises. A nozzle that gives a mist at 10 bar may give a fog at 20 bar, which is why the terms mist nozzle and fog nozzle are often used interchangeably. The rule is simple: higher pressure, smaller droplets.
Droplet size classes for mist and fog nozzles
Typical Sauter mean droplet sizes used to describe fine sprays.
| Class | Droplet size (Sauter mean) | Typically produced by |
|---|---|---|
| Dry fog | Below about 20 microns | Ultrasonic and high-energy atomizing nozzles |
| Wet fog | About 20 to 30 microns | Air atomizing and high pressure fog nozzles |
| Mist | About 30 to 60 microns | High pressure and mid pressure mist nozzles |
| Spray | Above about 60 microns | Standard hydraulic spray nozzles |
Our mist nozzle and fog nozzle range
Choose by system pressure and application. Every item can be quoted with fittings, filters and pipe to suit.
High pressure mist nozzle
Fine mist for high pressure misting systems used in outdoor cooling, industrial cooling and fogging.
| System | High pressure pump |
|---|---|
| Material | Brass / stainless steel |
Low pressure push-fit mist nozzle
Push-fit nozzle for low pressure lines, quick to install on tubing for patios, sheds and greenhouses.
| System | Low pressure |
|---|---|
| Connection | Push-fit |
Low pressure water mist nozzle 8 mm push-fit
Push-fit mist nozzle for 8 mm tubing on low pressure misting lines.
| Tube size | 8 mm |
|---|---|
| Connection | Push-fit |
Mist nozzle for dust suppression
Fine mist that captures airborne dust at conveyors, crushers and transfer points.
| Application | Dust suppression |
|---|
Mist nozzle for outdoor cooling
For cooling outdoor seating, terraces and open work areas by flash evaporation.
| Application | Outdoor cooling |
|---|
Industrial mist nozzle
Robust mist nozzle for factory humidification and process cooling.
| Application | Industrial cooling and humidification |
|---|
Sanitizer anti-drip low pressure mist nozzle
Anti-drip design closes cleanly when the pump stops, avoiding drips on people and surfaces.
| System | Low pressure |
|---|---|
| Feature | Anti-drip |
Mist nozzle designs and materials
Three common designs are used to make a fine mist:
- Small orifice nozzles force water through a very small hole; shear forces break it into droplets.
- Impingement nozzles strike the water on a pin just below the orifice to shatter it into very fine drops.
- Air atomizing nozzles use compressed air to break up the liquid, giving fine fog even at low water pressure.
For materials, look for brass bodies with a stainless steel tip or an SS316 nozzle. Cheaper plastic nozzles, or brass nozzles without a stainless tip, wear quickly and lose their pattern. Ceramic inserts are often used on high pressure misting fans for the finest mist. Our mist nozzles are made from industry-standard SS316 and brass, and come in a range of orifice sizes for pressures from about 30 to 1500 psi.
Applications for mist and fog nozzles
Cooling and climate control
Flash evaporation cools open areas, sheds and outdoor seating.
Dust control
Fine droplets bind airborne dust at crushers, conveyors and stockpiles.
Humidification
Keeps humidity steady in textile mills, printing and storage.
Greenhouses and gardens
Propagation, cooling and humidity for nurseries and landscaping.
Poultry and livestock
Reduces heat stress in poultry houses, dairies and animal sheds.
Odour control and gas scrubbing
Disperses odour-neutralising agents and scrubs gases at waste sites.
Keeping mist nozzles clean
Fine orifices clog if water is not filtered, so always fit a filter ahead of the pump and nozzles; some nozzles include their own filter screen. Clean nozzles at regular intervals. A simple method is to remove the nozzle and soak it overnight in a vinegar and water solution, then tap out the loosened scale. Use a soft brush or cloth, never a pin or sharp tool, which damages the orifice and spoils the spray. Replace nozzles that drip or spray unevenly after cleaning.
What to send with your mist nozzle enquiry
Not sure about some details? Send what you have — we will ask the right follow-up questions.
- Application: cooling, humidification, dust control, greenhouse or odour control
- Pump type and working pressure (low, mid or high pressure)
- Tube or pipe size and connection type
- Number of nozzles and area to be covered
- Water source and quality (hardness, filtration in place)
- Whether anti-drip nozzles are needed
Related misting and spraying pages
Is a fog nozzle the same as a mist nozzle?
Often, yes. The difference is droplet size, and droplet size depends on pressure. The same hydraulic nozzle can produce a mist at a lower pressure and a fog at a higher pressure. Fog is generally below about 30 microns and mist about 30 to 60 microns, so the two terms are commonly used for the same product.
What pressure do mist nozzles need?
It depends on the nozzle and the droplet size you want. Low pressure nozzles run off a booster or small pump and give a wetter mist. High pressure misting systems typically run around 70 bar (about 1000 psi) for fine, flash-evaporating mist. Our nozzles cover roughly 30 to 1500 psi depending on model and orifice.
Why do mist nozzles drip?
Dripping usually comes from low pressure at start-up or shut-down, a worn or partly blocked orifice, or a damaged seal. Anti-drip nozzles have a check valve that closes when pressure falls, stopping drips. Cleaning or replacing worn nozzles and keeping pressure in the right range also helps.
Which is better, brass or stainless steel mist nozzles?
Brass bodies with stainless steel tips are a good, economical choice for most cooling and humidification jobs. Full SS316 nozzles resist corrosion better and suit chemical dosing, coastal sites and harsh industrial duty. Avoid nozzles without a stainless tip, as the orifice wears quickly.
How often should mist nozzles be cleaned?
It depends on water quality and running hours. With hard water, check nozzles every few weeks during heavy use. Good filtration ahead of the pump greatly extends the interval. Soaking in a vinegar solution overnight removes most scale without damaging the orifice.
Can I buy mist nozzles without a full misting system?
Yes. We supply mist nozzles on their own as replacements or for your own system, as well as complete misting systems with pump, filters, tubing and controls.
Need mist or fog nozzles?
Tell us your pump pressure, application and quantity and we will send matching nozzles and a quotation.