Power quality & harmonics

Active harmonic filters in Mumbai and across India

Industrisol supplies active harmonic filters to plants and buildings in Mumbai and across India. An active harmonic filter measures the distorted load current and injects an equal and opposite current, cancelling harmonics in real time so your transformer, cables and sensitive equipment see a cleaner supply.

  • Reduces current THD from drives, UPS, rectifiers and LED lighting
  • Responds dynamically as loads change
  • Can also help with power factor and load imbalance, depending on model
  • Sizing support based on your harmonic data

Talk to our team

Need a price, alternative or spec check?

Share the model, quantity and application. We reply with suitable options and a quotation.

What is an active harmonic filter?

Non-linear loads such as variable frequency drives, UPS systems, rectifiers, induction heaters, computers and LED drivers draw current in pulses rather than as a smooth sine wave. That distorted current contains harmonics: currents at multiples of 50 Hz, mainly the 3rd, 5th, 7th, 11th and 13th.

An active harmonic filter, sometimes called an active power filter or harmonic correction unit, is connected in parallel with the load. Current transformers measure the load current, a controller calculates the harmonic content, and an IGBT-based inverter injects a compensating current of the same magnitude and opposite phase. It works like noise-cancelling headphones for your electrical network.

Because it is electronically controlled, an active harmonic filter tracks load changes within milliseconds and does not create resonance with the network, unlike passive filters. Most units cover harmonics up to around the 50th order and can be programmed to target specific harmonics.

Why plants install active harmonic filters

Active vs passive harmonic filtering

Point Active harmonic filter Passive / detuned filter
Principle Injects compensating current LC circuit absorbs or blocks harmonics
Harmonic range Many orders at once, typically up to about the 50th Mainly one or a few orders
Load changes Adapts automatically Fixed performance; can be under or over-loaded
Resonance risk None Must be designed to avoid it
Power factor Many models also correct displacement PF Corrects PF via capacitors
Typical cost Higher per ampere Lower; good for stable loads

How to size active harmonic filters

Active harmonic filters are rated in amperes of harmonic compensation current, not in kVAr. A good sizing exercise covers:

  • Measurement - log current THD and individual harmonics at the main incomer or the target feeder over a full production cycle.
  • Harmonic current - estimate the RMS harmonic current to be removed. As a rough check, harmonic current is about load current multiplied by THDi, divided by the square root of (1 + THDi squared).
  • Connection point - central filtering at the main LT panel, or local filtering at large drive or UPS feeders.
  • Neutral current - for 3rd harmonic and neutral overload problems, choose a 4-wire filter.
  • Margin and expansion - allow headroom and choose a modular design if loads will grow.

Targets are often set with reference to IEEE 519, which many utilities and consultants in India use for harmonic limits at the point of common coupling.

Active harmonic filter supply

Active harmonic filters

Panel-mounted and wall-mounted active harmonic filters for LT networks, in 3-wire and 4-wire versions. Share your harmonic data and we will propose a suitable rating.

Connection Parallel (shunt), via CTs
Network LT, 3-wire or 4-wire
Rating basis Amperes of compensation

What to include in your enquiry

Not sure about some details? Send what you have — we will ask the right follow-up questions.

  • System voltage and whether you need 3-wire or 4-wire compensation
  • Transformer rating and main incomer current
  • Harmonic measurement report or THD readings, if available
  • Main non-linear loads (VFDs, UPS, rectifiers, furnaces, LED lighting)
  • Target THD limit, if specified by your utility or consultant
  • Preferred mounting and the space available in the panel room

FAQ

Frequently asked questions

Still have a question? Call +91 90433 36700 or send an enquiry.

What does THD mean?

Total harmonic distortion compares the combined harmonic content of a waveform to its fundamental 50 Hz component, expressed as a percentage. Current THD (THDi) shows how distorted the load current is; voltage THD (THDv) shows how distorted the supply voltage has become. High THDi causes heating and tripping; high THDv can disturb other equipment on the same network.

How is an active harmonic filter different from an APFC panel?

An APFC panel switches capacitors to correct displacement power factor at 50 Hz. It does not remove harmonics, and plain capacitors can even amplify them. An active harmonic filter injects current to cancel harmonics. Many plants use both: a detuned APFC panel for bulk power factor correction and an active filter for harmonics.

Where should an active harmonic filter be installed?

For overall compliance, it is usually connected at the main LT panel near the transformer. If a few large drives or UPS systems cause most of the distortion, local filters on those feeders can be more effective and reduce cable heating upstream. The current transformers must be placed so the filter sees the load current it is meant to correct.

Can an active harmonic filter improve power factor?

Many active filters can also compensate reactive current and correct load imbalance, using spare capacity after harmonic correction. This is useful for fast-changing loads. For large, steady reactive demand, a capacitor-based APFC panel is usually more economical, with the active filter focused on harmonics.

Do I need a harmonic study before buying?

It is strongly recommended. Measured data shows which harmonics are present and how large they are, so the filter is neither undersized nor oversized. If no data is available, share your load list, transformer rating and the problems you are seeing, and we can discuss next steps.

Bring your harmonics under control

Send your load details and THD readings and we will reply with active harmonic filter options and a quotation.