Industrial automation · Panasonic
Panasonic VFD in India: inverters for induction motors
Industrisol supplies Panasonic VFD in India for speed control of standard induction motors on pumps, fans, conveyors, cranes, textile and CNC spindle applications. Tell us the motor kW, supply and application, and we will quote a suitable Panasonic inverter for your site in Mumbai or anywhere in India.
- Single-phase 230 V and three-phase 415 V models
- Sensorless vector control and built-in PID
- Modbus RS-485 communication
- Sizing help by motor kW and load type
What a Panasonic VFD does for your motor
A variable frequency drive changes the frequency and voltage supplied to an AC induction motor, so the motor runs at the speed the process needs instead of full speed all the time. On centrifugal pumps and fans this cuts energy use sharply, because power falls roughly with the cube of speed. On conveyors, mixers and machines it gives soft starting, adjustable speed and controlled stopping, which reduces mechanical shock on belts and gearboxes.
Panasonic VFDs combine sensorless and flux vector control for good torque at low speed, a built-in PID loop for pressure or flow control, and Modbus RS-485 for connection to a PLC or SCADA. If you need precise positioning rather than speed control, a servo system is the right choice; see Panasonic AC servo drives.
Panasonic VFD ranges we supply
Panasonic AVF200 series, 1-phase and 3-phase
The AVF200 is a compact universal inverter for general-purpose motor control. Single-phase 230 V models cover small machines and pumps; three-phase 415 V models cover larger conveyors, fans and process drives.
| 1-phase 230 V models | AVF200-0022, 0042, 0072, 0152, 0222 |
|---|---|
| 3-phase 415 V models | AVF200-0074, 0154, 0224, 0374, 0554, 0754, 1104, 1504 |
| 1-phase power range | 0.2 kW to 2.2 kW |
| Input frequency | 50 Hz |
Panasonic VFD, 0.037 to 354.2 kW, digital
The wider Panasonic inverter range with a digital keypad covers very small to large motors. Features include sensorless and flux vector control, a built-in EMI filter, PID feedback control, an inbuilt PLC function, auto energy-saving and zero-speed holding torque above 150%. Typical uses are elevators and elevator doors, treadmills, textile machines, cranes, CNC spindles, fans and pumps.
| Motor power | 0.037 to 354.2 kW |
|---|---|
| Input | 380 to 460 V, 50/60 Hz; single or three phase models |
| Output | 380 to 460 V, 0.5 to 400 Hz |
| Control | Sensorless vector, flux vector, PID |
| Communication | Modbus RS-485 |
| Example model | AVF200-0754, 7.5 kW |
Panasonic BFV00042G inverter, 0.4 kW
BFV00042G is a compact 0.4 kW Panasonic inverter for small motors on single-phase supply, often found on older machines and as a replacement spare. Speed can be set from the keypad, an external potentiometer, an analog input or a PWM signal.
| Power | 0.4 kW |
|---|---|
| Input | 1-phase 200 to 230 V, 50/60 Hz |
| Output frequency | 0.5 to 250 Hz |
| Overload | 150% current for 1 minute |
| Supply tolerance | +10% / -15% |
| Frequency setting resolution | 0.1 Hz |
Sizing a Panasonic VFD in India: quick guide
| Check | Guidance |
|---|---|
| Motor full-load current | Choose a VFD whose rated output current is at least the motor FLC |
| Load type | Pumps and fans are variable torque; conveyors, mixers and cranes are constant torque and may need a larger frame |
| Supply | Single-phase 230 V models for small motors; three-phase 415 V for most industrial motors |
| Duty | Frequent starts or heavy braking may need a braking resistor |
| Environment | Panel ventilation, dust and ambient temperature affect derating |
| Control | Keypad, potentiometer, 0 to 10 V / 4 to 20 mA or Modbus |
Send these details for a VFD quotation
Not sure about some details? Send what you have — we will ask the right follow-up questions.
- Motor kW, voltage and full-load current (nameplate photo)
- Application: pump, fan, conveyor, crane, spindle or other
- Supply: 1-phase 230 V or 3-phase 415 V
- Control method: keypad, analog signal or Modbus
- Existing VFD model if this is a replacement
- Quantity and site location
Can a single-phase Panasonic VFD run a three-phase motor?
Yes, within limits. Single-phase input inverters such as the 230 V AVF200 models produce a three-phase output, so they can run a small three-phase motor wired for 230 V (usually delta) from a single-phase supply. This works for motors up to about 2.2 kW. Larger motors need a three-phase supply and a three-phase input VFD.
How much energy can a VFD save on a pump or fan?
On centrifugal pumps and fans, power falls roughly with the cube of speed, so running at 80% speed needs only about half the power of full speed. Real savings depend on how often the load runs below full flow and on how flow was controlled before, for example by throttling valves or dampers. A short load survey gives a realistic estimate.
What is sensorless vector control?
Sensorless vector control estimates the motor’s magnetic flux and torque from current and voltage measurements, without an encoder. It gives stronger torque at low speed and better speed holding under load than simple V/f control. It suits conveyors, mixers and cranes; for precise positioning you still need a servo system.
Do I need a braking resistor with my VFD?
You need one when the load drives the motor back faster than the set speed, for example when a heavy fan or flywheel is stopped quickly, or on cranes and inclined conveyors when lowering. Without it the VFD trips on DC bus overvoltage. For pumps and lightly loaded conveyors with normal ramps, it is usually not required.
Can a Panasonic VFD connect to my PLC?
Yes. Panasonic VFDs support Modbus over RS-485, so a PLC or SCADA can start, stop, set speed and read status and faults. Simpler setups use digital inputs for run and direction and a 0 to 10 V or 4 to 20 mA analog signal for speed. Tell us your PLC model and we can suggest the wiring approach.
Get a Panasonic VFD quotation