Automation · Yaskawa
Yaskawa AC motors for inverter duty in India
We supply Yaskawa AC motors in India built for variable speed duty: MicroMAX, BlackMAX and BlueMAX inverter-duty induction motors and SyMAX permanent magnet motors. They are designed to run with a drive across a wide constant-torque speed range.
- Inverter-duty motors with up to 2000:1 constant torque speed range
- Options for PMDC replacement, dusty areas and cast iron builds
- Pairing advice with Yaskawa AC drives
- Supplied from Mumbai to customers across India
What makes an inverter-duty motor different
A standard induction motor is designed for fixed-speed operation on mains power. When it runs on a VFD at low speed, its shaft-mounted fan cools poorly and the fast-switching drive output stresses the winding insulation. Inverter-duty motors are built for this: better insulation systems, designs that hold full torque at low speed and provision for encoders and brakes.
The Yaskawa AC motors on this page are rated by their constant torque speed range, for example 1000:1 or 2000:1. A 1000:1 motor can deliver rated torque from base speed down to one-thousandth of base speed when driven by a suitable vector drive, which is why these motors are used on machine tools, winders, hoists and test stands.
Yaskawa AC motors: ranges we supply
Frame sizes, mounting and HP vary within each range. Send your required power, speed and mounting for a model-level quotation.
Yaskawa MicroMAX inverter-duty motor
MicroMAX is a three-phase vector duty motor designed as a direct replacement for PMDC motors when used with a VFD, removing brush and commutator maintenance. Typical uses include machine tools, conveyors, packaging, batching and printing equipment.
| Constant torque range | 1000:1 (TENV), 20:1 (TEFC) |
|---|---|
| Constant HP | To twice base speed |
| Insulation | Class H with 200 °C corona-resistant magnet wire |
| Mounting | Removable base for C-face footless mounting (as noted) |
| Conduit box | Top-mounted, as on PMDC motors |
| Duty | Continuous at 40 °C ambient |
Yaskawa BlackMAX inverter-duty motor
BlackMAX is a totally enclosed non-ventilated vector duty motor for material handling, cranes and hoists, metal processing, pumps, compressors and textile machinery, including installations in dusty or dirty areas.
| Constant torque range | 1000:1 |
|---|---|
| Enclosure | TENV, C-face, foot-mounted (except as noted) |
| Insulation | Class F MAXGUARD system |
| Provisions | Encoder and brake on opposite drive end |
| Design | NEMA Design A, ball bearings, Class F thermostats |
| Service factor | 1.0 on VFD |
Yaskawa BlueMAX inverter-duty motor
BlueMAX extends the speed range to 2000:1 constant torque and uses cast iron construction, for applications in dusty or dirty environments where cast iron frames are specified.
| Constant torque range | 2000:1 |
|---|---|
| Construction | Cast iron, totally enclosed, foot-mounted; C-face as noted |
| Insulation | Class H MAXGUARD system |
| Provisions | Encoder on opposite drive end |
| Bearings | Ball bearings (except as noted) |
| Duty | Continuous at 40 °C ambient |
Yaskawa SyMAX permanent magnet motor
SyMAX is an interior permanent magnet AC motor offering higher efficiency and power density than an equivalent induction motor, in normal NEMA or IEC mounting dimensions. It needs a drive that supports PM motor control.
| Efficiency | Significant energy savings over AC induction |
|---|---|
| Speed range | Up to 2000:1 constant torque; full torque at zero speed |
| Topology | Interior permanent magnet, low cogging design |
| Power factor | High |
| Vibration | Precision balanced to under 0.08 in/s |
| Mounting | Standard NEMA or IEC dimensions |
Comparing the Yaskawa AC motor ranges
| Range | Motor type | Speed range | Good fit for |
|---|---|---|---|
| MicroMAX | Induction, vector duty | 1000:1 TENV | Replacing PMDC motors on machines |
| BlackMAX | Induction, TENV | 1000:1 | Hoists, conveyors, dirty areas |
| BlueMAX | Induction, cast iron | 2000:1 | Heavy industry needing cast iron frames |
| SyMAX | Permanent magnet | Up to 2000:1 | Energy saving and high power density |
Information we need to quote a Yaskawa AC motor
Not sure about some details? Send what you have — we will ask the right follow-up questions.
- Power (kW or HP), base speed and supply voltage
- Required speed range and torque at lowest speed
- Mounting: foot, C-face or flange, and frame size if replacing
- Enclosure and environment: dust, moisture, ambient temperature
- Encoder or brake requirement
- Drive model in use or planned
- Quantity and delivery location
Can I run a standard induction motor on a VFD instead of an inverter-duty motor?
Often yes, for fans and pumps with a modest speed range. For long periods at low speed with full torque, long cable runs or high switching frequencies, an inverter-duty motor such as BlackMAX or BlueMAX is safer because of its insulation system and cooling design. We can help judge which your application needs.
What does 1000:1 constant torque mean?
It means the motor can deliver its rated torque continuously from base speed down to one-thousandth of that speed when controlled by a suitable vector drive. For a 1800 rpm motor that is down to about 1.8 rpm, without overheating.
Can MicroMAX replace a DC motor on my machine?
MicroMAX is designed as a direct replacement for PMDC motors when paired with a VFD, with a top-mounted conduit box similar to DC motors. Share the DC motor rating and mounting so we can check dimensions and recommend a drive.
Does a SyMAX permanent magnet motor need a special drive?
It needs a drive that supports permanent magnet motor control. Several Yaskawa AC drives, such as A1000 and GA800, support PM motors. Tell us your drive model and we will confirm compatibility before you order.
How do I get a price for Yaskawa AC motors?
Send power, speed, mounting, enclosure and quantity using Request a quote, or call +91 90433 36700. We quote current prices for the exact motor and can include a matching drive if needed.
Find the right Yaskawa AC motor
Send your speed, torque and mounting requirement and we will propose a Yaskawa motor, with a matching drive if required.