Automation · Yaskawa

Yaskawa AC motors for inverter duty in India

We supply Yaskawa AC motors in India built for variable speed duty: MicroMAX, BlackMAX and BlueMAX inverter-duty induction motors and SyMAX permanent magnet motors. They are designed to run with a drive across a wide constant-torque speed range.

  • Inverter-duty motors with up to 2000:1 constant torque speed range
  • Options for PMDC replacement, dusty areas and cast iron builds
  • Pairing advice with Yaskawa AC drives
  • Supplied from Mumbai to customers across India
Yaskawa BlueMAX inverter duty AC motor

What makes an inverter-duty motor different

A standard induction motor is designed for fixed-speed operation on mains power. When it runs on a VFD at low speed, its shaft-mounted fan cools poorly and the fast-switching drive output stresses the winding insulation. Inverter-duty motors are built for this: better insulation systems, designs that hold full torque at low speed and provision for encoders and brakes.

The Yaskawa AC motors on this page are rated by their constant torque speed range, for example 1000:1 or 2000:1. A 1000:1 motor can deliver rated torque from base speed down to one-thousandth of base speed when driven by a suitable vector drive, which is why these motors are used on machine tools, winders, hoists and test stands.

Yaskawa AC motors: ranges we supply

Frame sizes, mounting and HP vary within each range. Send your required power, speed and mounting for a model-level quotation.

Yaskawa MicroMAX inverter duty motor

Yaskawa MicroMAX inverter-duty motor

MicroMAX is a three-phase vector duty motor designed as a direct replacement for PMDC motors when used with a VFD, removing brush and commutator maintenance. Typical uses include machine tools, conveyors, packaging, batching and printing equipment.

Constant torque range 1000:1 (TENV), 20:1 (TEFC)
Constant HP To twice base speed
Insulation Class H with 200 °C corona-resistant magnet wire
Mounting Removable base for C-face footless mounting (as noted)
Conduit box Top-mounted, as on PMDC motors
Duty Continuous at 40 °C ambient
Yaskawa BlackMAX TENV inverter duty motor

Yaskawa BlackMAX inverter-duty motor

BlackMAX is a totally enclosed non-ventilated vector duty motor for material handling, cranes and hoists, metal processing, pumps, compressors and textile machinery, including installations in dusty or dirty areas.

Constant torque range 1000:1
Enclosure TENV, C-face, foot-mounted (except as noted)
Insulation Class F MAXGUARD system
Provisions Encoder and brake on opposite drive end
Design NEMA Design A, ball bearings, Class F thermostats
Service factor 1.0 on VFD
Yaskawa BlueMAX cast iron inverter duty motor

Yaskawa BlueMAX inverter-duty motor

BlueMAX extends the speed range to 2000:1 constant torque and uses cast iron construction, for applications in dusty or dirty environments where cast iron frames are specified.

Constant torque range 2000:1
Construction Cast iron, totally enclosed, foot-mounted; C-face as noted
Insulation Class H MAXGUARD system
Provisions Encoder on opposite drive end
Bearings Ball bearings (except as noted)
Duty Continuous at 40 °C ambient
Yaskawa SyMAX permanent magnet AC motor

Yaskawa SyMAX permanent magnet motor

SyMAX is an interior permanent magnet AC motor offering higher efficiency and power density than an equivalent induction motor, in normal NEMA or IEC mounting dimensions. It needs a drive that supports PM motor control.

Efficiency Significant energy savings over AC induction
Speed range Up to 2000:1 constant torque; full torque at zero speed
Topology Interior permanent magnet, low cogging design
Power factor High
Vibration Precision balanced to under 0.08 in/s
Mounting Standard NEMA or IEC dimensions

Comparing the Yaskawa AC motor ranges

Range Motor type Speed range Good fit for
MicroMAX Induction, vector duty 1000:1 TENV Replacing PMDC motors on machines
BlackMAX Induction, TENV 1000:1 Hoists, conveyors, dirty areas
BlueMAX Induction, cast iron 2000:1 Heavy industry needing cast iron frames
SyMAX Permanent magnet Up to 2000:1 Energy saving and high power density

Information we need to quote a Yaskawa AC motor

Not sure about some details? Send what you have — we will ask the right follow-up questions.

  • Power (kW or HP), base speed and supply voltage
  • Required speed range and torque at lowest speed
  • Mounting: foot, C-face or flange, and frame size if replacing
  • Enclosure and environment: dust, moisture, ambient temperature
  • Encoder or brake requirement
  • Drive model in use or planned
  • Quantity and delivery location

FAQ

Frequently asked questions

Still have a question? Call +91 90433 36700 or send an enquiry.

Can I run a standard induction motor on a VFD instead of an inverter-duty motor?

Often yes, for fans and pumps with a modest speed range. For long periods at low speed with full torque, long cable runs or high switching frequencies, an inverter-duty motor such as BlackMAX or BlueMAX is safer because of its insulation system and cooling design. We can help judge which your application needs.

What does 1000:1 constant torque mean?

It means the motor can deliver its rated torque continuously from base speed down to one-thousandth of that speed when controlled by a suitable vector drive. For a 1800 rpm motor that is down to about 1.8 rpm, without overheating.

Can MicroMAX replace a DC motor on my machine?

MicroMAX is designed as a direct replacement for PMDC motors when paired with a VFD, with a top-mounted conduit box similar to DC motors. Share the DC motor rating and mounting so we can check dimensions and recommend a drive.

Does a SyMAX permanent magnet motor need a special drive?

It needs a drive that supports permanent magnet motor control. Several Yaskawa AC drives, such as A1000 and GA800, support PM motors. Tell us your drive model and we will confirm compatibility before you order.

How do I get a price for Yaskawa AC motors?

Send power, speed, mounting, enclosure and quantity using Request a quote, or call +91 90433 36700. We quote current prices for the exact motor and can include a matching drive if needed.

Find the right Yaskawa AC motor

Send your speed, torque and mounting requirement and we will propose a Yaskawa motor, with a matching drive if required.